Celum installs and operates storage per supervisor through three backends. Each is a tab on the onboarding wizard’s Storage step, each reports day-2 state through the platform’s component-status model, and each ends the same way: one or more StorageClasses that every downstream consumer — tenant clusters, VMs, the Image Library, monitoring — provisions against. They are not exclusive. A supervisor commonly runs Ceph as its default class and adds NFS for bulk file storage; a SAN-attached supervisor can feed its FC LUNs to Ceph and keep HSPC installed side by side.

Choosing a backend

1

Local NVMe/SSD in the nodes — Rook-Ceph

The default path. Replicated block storage with snapshots and fast CSI clones, no external dependency. This is what the Image Library’s ~seconds golden-image cloning and VM live migration are built on.
2

An FC array behind the nodes — Rook-Ceph on SAN LUNs first

The shipped pattern is a Ceph san device class: the array carves a few large LUNs per node once (masked by WWPN), and Ceph consumes them as OSDs next to the local NVMe ones — same cluster, two tiers, separate pools. The array’s API is never in the runtime path, so provisioning is a Ceph operation (milliseconds), CSI clone works on FC capacity, and a path failure is absorbed by multipath or healed by replication. See Rook-Ceph.
3

Array-native data services required — HSPC

When a volume must be a first-class array object (one LDEV per PVC, array-side thin provisioning and snapshots), install the Fibre Channel backend. Expect array-API latency in the provisioning path and a hard multipath prerequisite on the nodes.
4

Existing NAS, file semantics — NFS

Simplest to stand up: server + export path, one StorageClass, a built-in test-PVC smoke check. Filesystem-mode only — fine for shared data, the slow path for VM images.

What lives where

  • Install and reconfigure happen on the wizard’s Storage step. Each tab is a chart release panel plus backend-specific forms; re-opening the step hydrates the forms from the supervisor, so re-apply expresses deltas rather than re-entering everything.
  • Day-2 status is the same status model as every other component: exists / ready / revision / conditions with the chart controller’s reason and message. Ceph adds a second, deeper status — cluster health, OSDs, mons, pools — read live from the CephCluster.
  • Disk inventory — every node’s block devices with model, size, transport (nvme / sata / fc / usb) and a lifecycle state — feeds the Rook disk picker and the Infrastructure page’s SAN LUN panel, where FC LUNs group by WWID with their multipath path counts.
  • Classes & profiles list every StorageClass and its CDI StorageProfile — the clone strategy and access-mode/volume-mode combinations that decide VM cloning speed and live-migration eligibility.
  • PVCs & snapshots browse actual claims and volume snapshots per namespace.
The in-product assistant, Celum AI, answers storage questions from these same APIs — “which class should this VM use?” or “why is Ceph degraded?” reads the identical status, class, profile, disk, and PVC data the panels render.

PVC Pending — the triage order

A Pending claim is the universal storage symptom. Work top-down:
1

Read the claim's events

The test-PVC diagnostic provisions a throwaway claim against any class and returns the PVC events on failure — the provisioner’s own error, without kubectl.
2

Does the class exist, and is its provisioner running?

Check the backend’s status panel. A deleted NFS driver leaves orphan StorageClasses that look valid but can never bind; a Ceph cluster can be healthy while the CSI provisioner is absent.
3

Can the class satisfy what was requested?

ReadWriteMany on a class whose profile only claims ReadWriteOnce, or Block mode on file-backed storage, pends forever. The profiles table shows what each class actually supports.
4

Is the backend itself healthy?

Ceph health warnings (OSDs down, degraded PGs), an unreachable NFS server, or a misconfigured FC port list all surface in the respective status — see the per-backend pages for their failure signatures.
The full checklist with per-cause signatures lives in PVCs & snapshots.

Permissions

All storage backend operations map to the storage action family, scoped to krn:vks:supervisor:<supervisor>:storage:*: Ceph cluster health reads use ceph:GetStatus on krn:vks:supervisor:<supervisor>:ceph:*. The snapshot controller and the namespace-scoped PVC/snapshot listings have their own families — see the per-page tables.

The Storage pages

Rook-Ceph

Local-disk and SAN-LUN installs, the disk picker and wipe flow, Ceph health, and rollback recovery.

NFS & Fibre Channel

The external backends — NFS driver and storage classes, HSPC discover/install/status, multipath.

Classes & profiles

StorageClasses, CDI StorageProfiles, and which class to give VMs and golden images.

PVCs & snapshots

The per-namespace claim browser, volume snapshots, the snapshot controller, and the Pending checklist.